The ETMAN-S series multi-purpose cabinet is a multifunctional cabinet used to install and protect network equipment, other active equipment, and manage wiring. Its design is unique and novel, with a beautiful appearance.
Product technical features:
★ The assembled structure is suitable for the development of today's technology
★ Sturdy pile frame structure with a load capacity of 500kg
★ Unique design, lightweight and sturdy ventilation door, with a ventilation area of up to 80%
★ Compatible with both 19 "and 21" devices
★ Three section 19 "and 21" instrument installation angle gauge
★ Multiple high-capacity strong and weak current routing schemes. Flexible cable management makes wiring more convenient
★ Green, energy-saving, and heat saving solutions
★ Hidden PDU installation solution Fang Qin
★ Customized solutions
Collaborating structure
Suitable for the requirements of today's technology, easy to install, operate, maintain on-site, and reduce customer costs.
1. Open Framework
Consisting of two welded frames
2. Lightweight and sturdy front and rear ventilation doors
The hexagonal hole is 6.35mm on the opposite side and 0.72mm on the overlap, with a ventilation area of over 80% and extremely high ventilation performance; Adopting a closed bending spot welding process, the door position body is lightweight, sturdy, and does not shake, with a beautiful appearance and simple lines; 1.2mm thick high-quality cold-rolled steel plate; The door opening degree reaches 130 degrees; Hinge design makes door disassembly convenient; When there are openings in the computer room space, double doors can be used.
3. Sides
It can be quickly disassembled and installed, and a safety lock can be installed on the side door.
4.19 "Three section instrument installation angle gauge
Fixed installation on the column or on the inverter, the installation position can be adjusted in the depth direction, and different installation depths can be provided within a cabinet. (The adjustable 3-section instrument installation angle gauge is only limited to 600mm wide cabinets and cabinets with a height of 42U or above).
5. Cabling solutions
A square 440mm * 380mm covered cable inlet hole and two 60mm * 340mm rectangular inlet holes (standard configuration) for the top incoming line; In addition, the ventilated flat top cover can reduce the overall height of the cabinet while ensuring effective use, facilitating its transportation and handling, and increasing air circulation to improve heat dissipation.
The bottom inlet can be equipped with square 440mm * 380mm electrical system inlet holes and two 60mm * 340mm rectangular inlet holes (standard configuration; side wiring -800mm wide cabinet (standard configuration, 100mm wide wiring space on the left and right sides).
6. Various accessories - large capacity cable trays
The 800mm wide cabinet can be equipped with a covered and locked wiring slot -100mm wide and 66mm deep, which can meet the needs of high-capacity wiring.
Various accessories - keyboard and mouse tray
Ergonomically adjustable keyboard and mouse tray with a height of 2U, with a lock and a removable mouse pad.
7. Cooling solution
Depending on the depth of the cabinet, different top mounted fans can be installed without occupying the actual effective usage space inside the cabinet; The extremely high ventilation rate of the front and rear mesh doors ensures the heat dissipation requirements of the equipment, including the ventilation top cover and ventilation bottom.
Customized solutions
IES not only meets the needs of standardized products, but also supports the needs of customized products for customers; Providing personalized products and services to customers is IES' consistent commitment to global and long-term partners.
With the widespread acceptance of the concept of green data centers, energy efficiency (PUE) has become one of the important measurement indicators.
PUE=Total electricity consumption of data center/IT equipment electricity consumption
A better energy-saving computer room typically has a PUE of 2-1.6, which represents an improvement in the efficiency of IT equipment usage and a decrease in energy consumption of other equipment. The most important aspect is the improvement in heat dissipation efficiency.
In recent years, various solutions for dry cooling have put forward natural requirements for the ventilation status of the cabinet itself, that is, the ventilation capacity of the cabinet itself directly affects the implementation effect of the overall cooling solution. Any overall cooling solution requires the cabinet itself to have good ventilation rate.
Definition of ventilation rate for mesh doors. |
Evaluation of ventilation rate
Circular hole diameter: 5.0mm |
Hexagonal aperture: 8.0mm |
Hexagonal aperture: 6.35mm |
The characteristics of IES mesh doors.
1. Cold rolled steel plate 1.2mm-1.5mm, with a ventilation rate of up to 80.6%;
2. The overall flatness of the mesh door is less than 3.00mm;
3. When the overlap of the hexagonal hole is less than 0.72mm, there is no fracture phenomenon;
4. Processing ability of irregular mesh holes;
In terms of molding, CNC machining molds and welding fixtures are complete, and can process various types of mesh doors.