The ETMAN-I series server cabinet is an excellent cabinet for dry installation and protection of servers and other active devices. It integrates the functions of various server cabinets in the current market and continuously develops and innovates. It has the characteristics of safe and reliable use, unique functions, diverse wiring management solutions, good heat dissipation effect, and convenient installation.
Product technical features:
★ Assembled structure suitable for today's technological development, sturdy frame structure with a load capacity of 1000kg
★ Unique design, lightweight and sturdy ventilation door, with a ventilation area of up to 82%
★ Three section 19 "instrument installation angle gauge
★ Multiple high-capacity strong and weak current routing schemes. Flexible cable management makes wiring more convenient
★ Green energy-saving heat dissipation solution
★ Hidden PDU installation solution
★ Customized solutions
Modular structure
Suitable for the requirements of today's technology, easy to install, transport, on-site maintenance, etc., and reducing customer costs.
1: Open Framework
Including four columns (70% folded), welded upper and lower bottom frames (welded with sturdy aluminum alloy castings at each corner, totaling 8 aluminum alloy castings).
2: Lightweight and sturdy front and rear ventilation doors
The hexagonal hole is 6.35mm on the opposite side and 0.72mm on the overlap, with a ventilation area of over 80% and extremely high ventilation performance; Adopting a closed bending spot welding process, the door is lightweight, sturdy, and does not shake, with a beautiful appearance and simple lines; 1.2mm thick high-quality cold-rolled steel plate; The door opening reaches 120 degrees; Hinge design makes door disassembly convenient; When the space in the computer room is limited, double doors can be used.
3: 19 "Three section instrument installation angle gauge
Fixed on the column or stabilizer, the installation position can be adjusted in the depth direction; Different installation depths can be provided in one cabinet. (The adjustable 3-section instrument installation angle gauge is only limited to 60mm wide cabinets and cabinets with a height of 42U or above.)
4: Cabling solutions
Top incoming square: 350mm * 240mm cable inlet hole with cover and two 80mm * 120mm elliptical inlet holes (standard configuration); Chimney type trunking with adjustable inlet capacity (optional);
Top Cable Management - Various cable management components at the top of cabinets (optional), which can achieve top cable management for a single cabinet or multiple parallel cabinets;
An 80mm * 120mm elliptical inlet hole for the bottom incoming line (optional); Multi segment detachable long strip inlet hole (optional);
A new type of large capacity 180mm * 45mm cable tray with half moon shaped inlet holes on the side (standard configuration, only for dry 600mm wide cabinets), 800mm wide cabinets (standard configuration, 100mm wide cable space on the left and right sides).
5: Various accessories - Large capacity cable trough
The 800mm wide cabinet can be equipped with a covered and locked wiring slot -100mm wide and 66mm deep, which can meet the needs of high-capacity wiring. Various accessories - a keyboard and mouse tray with a height of 2U that conforms to ergonomics. It is a retractable keyboard and mouse tray with a lock and a removable mouse pad.
6: PDU Hidden Installation Solution
High density vertical mounted PDU can be installed on a 600mm wide cabinet without affecting the installation of 19 "equipment
7: Cooling solution
Depending on the depth of the cabinet, different top mounted fans can be installed without occupying the actual effective usage space inside the cabinet; The extremely high ventilation rate of the front and rear mesh doors ensures the heat dissipation requirements of the equipment, including the ventilation top cover and ventilation bottom.
Customized solutions
IES not only meets the needs of standardized products, but also supports the needs of customized products for customers; Providing personalized products and services to customers is IES' consistent commitment to global and long-term partners.
With the widespread acceptance of the concept of green data centers, energy efficiency (PUE) has become one of the important measurement indicators.
PUE=Total electricity consumption of data center/IT equipment electricity consumption
A better energy-saving computer room typically has a PUE of 2-1.6, which represents an improvement in the efficiency of IT equipment usage and a decrease in energy consumption of other equipment. The most important aspect is the improvement in heat dissipation efficiency.
In recent years, various solutions for dry cooling have put forward natural requirements for the ventilation status of the cabinet itself, that is, the ventilation capacity of the cabinet itself directly affects the implementation effect of the overall cooling solution. Any overall cooling solution requires the cabinet itself to have good ventilation rate.
Definition of ventilation rate for mesh doors. |
Circular hole diameter: 5.0mm |
Hexagonal aperture: 8.0mm |
Hexagonal aperture: 6.35mm |
Maximum width of mesh: 720mm |
Maximum width of mesh: 670mm |
Maximum width of mesh: 680mm |
The characteristics of IES mesh doors.
1. Cold rolled steel plate 1.2mm-1.5mm, with a ventilation rate of up to 80.6%;
2. The overall flatness of the mesh door is less than 3.00mm;
3. When the overlap of the hexagonal hole is less than 0.72mm, there is no fracture phenomenon;
4. Processing ability of irregular mesh holes;
In terms of molding, CNC machining molds and welding fixtures are complete, and can process various types of mesh doors.